ABSTRACT
Accurate and rapid evaluation of SARS-CoV-2 half-maximal neutralizing antibody (nAb) titer (NT50) is an important research tool for measuring nAb responses after prophylaxis or therapeutics for COVID-19 prevention and management. Compared with ACE2-competitive enzyme immunoassays for nAb detection, pseudovirus assays remain low-throughput and labor intensive. A novel application of the Bio-Rad Bio-Plex Pro Human SARS-CoV-2 D614G S1 Variant nAb Assay was used to determine NT50 from COVID-19-vaccinated individuals and showed strong correlation to a laboratory-developed SARS-CoV-2 pseudovirus nAb assay. The Bio-Plex nAb assay could provide a rapid, high-throughput, culture-free method for NT50 determination in sera.
Subject(s)
COVID-19 , RNA Viruses , Humans , SARS-CoV-2 , COVID-19/diagnosis , Antibodies, Viral , Antibodies, Neutralizing , Angiotensin-Converting Enzyme 2ABSTRACT
Anti-severe acute respiratory syndrome coronavirus 2 (anti-SARS-CoV-2) nucleoprotein (NP) antibodies were isolated from pig sera using human SARS-CoV-2 NP-immobilized magnetic beads. The binding properties of the isolated antibodies against SARS-CoV-2 NP were tested via flow cytometry using SARS-CoV-2 NP-immobilized magnetic beads. A competitive immunoassay was developed for detecting SARS-CoV-2 NP as well as SARS-CoV-2 in the culture fluid using magnetic beads with immobilized anti-SARS-CoV-2 NP antibodies. Selectivity tests were carried out during the competitive immunoassay for SARS-CoV, MERS-CoV, and CoV strain 229E in the culture fluid.